- Granite[1]
- Mazut[9]
- Keyboards[18]
- Other Machinery[1]
- Contact Person : Ms. Li Honglian
- Company Name : Tianjin Longcheng Automation Instrument Co., Ltd.
- Tel : 86-22-26712291
- Fax : 86-22-26712297
- Address : Tianjin,Tianjin,No.9, First spur track,Fenhe south road, Qinjian industry area ,Tiedong Road,Beichen District
- Country/Region : China
- Zip : 300402
actuating element
Detailed Product Description
actuating element Part-turn actuators :
Type | Rated torque | Travel time | Ball hinge type | ||||||
SH-160/K40H | 1600 | 40,28 | SQJ-160 | ||||||
SH-160/F40H | 1600 | 40,28 | SQJ-160 | ||||||
SH- |
|
|
|
|
|
| Code | ||
| / |
|
|
|
| The maximum output torque, numbers that, unit: Nm | |||
| K |
|
|
| Power codesignal phase220V/50Hz | ||||
F |
|
|
| Power code3- phase 380V/50Hz | |||||
|
|
| Rated travel time, number of that unit; S | ||||||
| H |
| Installation Type | Base type | |||||
Z |
| Direct-coupled type | |||||||
| L | Control Characteristics | 2 Type | ||||||
Unsigned | The overall proportion of type 4-20mA | ||||||||
S | Discrete proportional 4-20mA | ||||||||
Y | Remote control-type | ||||||||
Main Technical Performance:
The following technical performance mainly refers to the proportion of adjustable type, on the far-controlled and the switching of the following 1,2,3,4,5,6,11,12,13,14 did not concern.
1, input signal: 4mA-20mA DC or 1V-5V DC;
2, enter the channel resistance; 250Ω;
3, input channel number: 1 (discrete formula 3);
4, the basic error: ± 1, ± 2.5%;
5, hysteresis: 1%, 1.5%;
6, dead-0.5-3% (can be set according to system requirements);
7, damping properties: no swing
8, power supply voltage: single phase 220V (+10%, -15%) 50Hz ± 1% Three-phase 380V ± 10% 50Hz ± 1%
9, the working environment: temperature: Integral -10 - +55 ; discrete -25 - +70 ; Humidity: ≤ 85%, ambient air does not contain corrosive substances;
10, shell protection grade; meet GB4208 IP65 (dust or rain);
11, broken signal protection functions: preset There are three ways: a, in situ, b, fully open, c, Fully closed;
12, over-current protection function: pairs of different types of models, to protect current value adjustable; (mechanical parts there have been moments Protection Switch)
13, the dynamic electrical braking function;
14, the ceiling and the lower limit function: at rated travel within the range of upper and lower limits adjustable About 40%; (mechanical parts of a stroke control switches and mechanical limit)
15, the working system; reversible intermittent working system, connected to sustained rate of 50% per hour, the number of connected
1200 times.